Instrument knowledge|How to choose the correct type of guided wave radar level gauge?

DATE: 2021-05-11
BROWSE TIMES: 360

Guided wave radar level gauge, a liquid level measuring instrument in industrial production, is based on the time domain reflection principle (TDR) to complete the continuous level measurements of liquids, particles and slurry. Widely used in water storage tanks, acid and alkali storage tanks, slurry storage tanks, solid particles, small oil storage tanks, various conductive, non-conductive media, corrosive media such as coal bunkers, ash bunkers, oil tanks, acid tanks, etc. .

So how to correctly choose the guided wave radar level gauge? Please see the following key selection points:

Instrument knowledge|How to choose the correct type of guided wave radar level gauge?

1.Confirm the viscosity of the measuring medium

When selecting a guided wave radar level gauge, the viscosity of the measuring medium must be confirmed. If the measuring medium is very viscous, it is not suitable to use the guided wave cable pole. This kind of contact measurement method, hanging material will affect the signal transmission and reception and generate false signals.

2.Confirm the causticity of the measured medium

If the measured medium is a corrosive liquid, it is necessary to use a wave guide cable sleeve PTFE or FEP material.


3.Definition of range

The range of the guided wave radar level gauge is the vertical distance from the mounting flange surface to the bottom of the tank. At the same time, reserve the lowest probe of the cable at least 30mm from the bottom of the tank to ensure that the probe does not touch the bottom of the metal tank to generate interference signals. The cable can be reserved a little longer, you can cut it by yourself, but if you break it, you need to re-customize the cable. Therefore, we must confirm the length of the cable clearly when determining the technical parameters, so as to avoid the on-site measurement.

In addition, it is especially important to note that for the guided wave radar level meter with sleeve PTFE or FEP material products, the cable length cannot be shortened once confirmed


4.Confirm whether there is stirring

Select the guided wave radar level gauge to confirm whether there is stirring in the storage tank, where is the position of the fan blade, the blade is very close to the pipe wall, it is not suitable to use the guided wave radar level gauge, or add a bypass tube to measure. The cable or pole should be at least 300mm away from the pipe wall.

5.Confirm the dielectric constant of the measuring medium

If the measured dielectric constant of the liquid medium is very low, you can refer to the use of guided wave double cable or guided wave coaxial radar level gauge, the effect will be better.

6.Fixing the probe tip of radar level gauge

If the probe tip needs to be fixed, there are two kinds of fixing methods: insulated and non-insulated.

(一)Insulation fixing refers to the insulation fixing method when the measured dielectric constant is low and fixed on the bottom of the metal tank

(二)Non-insulating fixing refers to the non-insulating fixing method used when the dielectric constant of the measured medium is high and the tank is a metal material, a material with a low dielectric constant or a material very close to the dielectric constant of the measured medium.


Any inquiry of radar level meter, welcome to contact us!


Share to
RELATED NEWS / News More
  • Number of clicks: 287
    2021 - 08 - 24
    Our 120GHz frequency modulated radar level meter has been successfully applied to the oil project. The project mainly produces edible vegetable oil, sprayed corn germ meal, corn germ meal, corn germ cake, vegetable meal, vegetable cake, corn gluten meal, corn gluten feed, and corn For products such as meal, the 120GHz frequency modulation radar level gauge is used to measure the level of medium such as vegetable oil and corn steep liquor in the tank area of the project.On-site working conditions and parametersMedium: vegetable oil, corn steep liquorRange: 0-20mExplosion-proof type: flameproof typeOperating temperature: 50—70°COperating pressure: slight negative pressureOutput type: (4-20) mA/24V DC/HART four-wire systemProduct model: DCRD1000B1Working condition description: The storag...
  • Number of clicks: 359
    2021 - 08 - 17
    1. Primary instrument and secondary instrument are idioms used in instrument installation engineering. The exact name should be measuring instrument and display instrument. The measuring instrument is in direct contact with the medium and is installed on-site outdoors, while the display instrument is mostly installed on the control room panel. In order to distinguish the instruments in a set of systems, the instruments installed on-site are referred to as primary instruments, and the panel-mounted display instruments are referred to as secondary instruments. The professional interpretation of the secondary instrument is an instrument that accepts electrical or gas signals sent by transmitters, converters, sensors (including thermocouples, thermal resistances), etc., and indicates the measu...
  • Number of clicks: 397
    2021 - 08 - 10
    An environmental protection energy company in Xinjiang is mainly engaged in the investment, development, construction, operation and management of projects such as environmental protection and energy conservation, comprehensive utilization of resources, and circular economy. The company focuses on the qualitative utilization of coal in Xinjiang, focusing on energy conservation, environmental protection, comprehensive utilization of resources, and the development of circular economy. 'Integrated Circular Economy and Comprehensive Utilization of Resources Demonstration Park.Our DCRD1000A series sensor is a 26G high frequency radar type level measuring instrument, output 4-20mA analog signal, the maximum measuring distance can reach 70 meters. The antenna is further optimized, and the new...
  • Number of clicks: 357
    2021 - 08 - 03
    Maintenance example: troubleshooting and maintenance of radar level meter F1401. Instrument type: 26G high frequency radar level meter2. Failure category: F1403. Failure analysis: F140 means that the echo signal is weak or there is no echo signal.So, how to solve this problem? The specific operations are as follows:Step 1:Troubleshooting on sitea. Check that the range set by the radar must be greater than the total range of the tank.b. When the measured medium is liquid, check whether the radar sensor enters water vapor.When the measured medium is solid, it needs to be checked for crystallization or excessive dust accumulation.The above cleaning is complete and reinstalled, and then adjust the radar angle until the radar echo signal is the strongest.Step 2: Oscilloscope test and repai...
  • Number of clicks: 369
    2021 - 07 - 27
    Radar level transmitter are currently widely used in the monitoring of solids, dust particles, liquids, slurries, river water levels, etc. The level signal detected by the radar level transmitter is ultimately connected to the back of our automation control equipment or to the secondary display meter for monitoring control. The specific power supply and communication methods are as follows:1. (4 ~ 20) mA / 24V DC / HART two-wire system2. (4 ~ 20) mA / 24V DC / HART four-wire system3. (4 ~ 20) mA / (85~ 265) V AC / HART four-wire system4. RS485/Modbus/( 6~26)V DC5. Radio frequency 433MThe customer can select the power supply and communication mode according to the actual requirements of the site. If you have any questions, please contact us directly.Xi’an Dechuang Electrical ...
Email:sales@dechuang-auto.com
Adress:
Tel:86-29 88606479
Fax: 86-29 88385903
B203, Gazelle Valley, No.69 Jinye Rd, Hi-tech zone, Xi'an, Shaanxi Province, P.R.China. 710077
Copyright ©2018 - 2019 Dechuang Electrical Technology Co., Ltd SITEMAP
Rhino Cloud Provides Enterprise Cloud Services
犀牛云提供云计算服务