The working principle and five precautions for using the radar level sensor

DATE: 2021-02-25
BROWSE TIMES: 4

The working principle and five precautions for using the radar level sensor

The radar level sensor is a measuring instrument based on the time travel principle. The radar wave runs at the speed of light, and the running time can be converted into a level signal by electronic components. The probe sends out high-frequency pulses and conducts them along the cable and rod probes. When the pulses meet the surface of the material, they are reflected back by the receiver in the meter, and the distance signal is converted into a level signal, Transmit-reflect-receive is the basic working principle of radar level sensor.

The antenna of the radar sensor emits electromagnetic wave signals in the form of beams. The emitted waves are reflected on the surface of the material to be measured, and the reflected echo signals are still received by the antenna. Every point in the transmitted and reflected beams is collected by ultrasonic sampling. After the signal is processed by the intelligent processor, the distance between the medium and the probe is obtained and sent to the terminal display for display.

 

And there are five Precautions when using the radar level sensor:

1. Given an accurate measurement range, working beyond the range makes the radar level sensor not only unable to obtain accurate measurement data, but may also cause damage to the radar level gauge. The measurement range should be calculated from the bottom of the tank where the light wave touches. If the tank is special and the bottom is concave, at this time the level is lower than the calculation point and measurement cannot be performed.

2. If the medium has a low dielectric constant, the bottom of the tank is visible when it is at a low liquid level. At this time, in order to ensure the measurement accuracy, it is recommended to move the zero position up appropriately.

3. When measuring low dielectric constant medium, if its level is lower than the measured value of the liquid level, and the bottom of the tank is visible, if you want to make the measurement more accurate, you can adjust the zero point upward to be higher than the bottom of the tank. position. Although the measurement range value can reach the top of the antenna tip, this is only in an ideal state. In reality, the effect of adhesion needs to be considered, so the measurement value should be fixed at least 100mm from the top of the antenna as far as possible.

4. If the measured medium is in constant motion, in order to ensure the accuracy of the measurement, it is recommended to install a bypass pipe on site and fix it at the middle of the bottom of the storage tank. During the welding process, the smoothness of the inner wall of the bypass pipe needs to be ensured. , In order to prevent the irregularities from obstructing the radar level measurements.

5. The radar level measurements varies with the concentration. The foam can not only absorb microwaves, but also reflect them; if there is foam in the tank, determine the thickness of the foam.

 

In recent years, radar level sensor have been the first choice for many users to measure the height of the liquid level. The use of the product must be properly grasped, so as to reduce the damage caused to the radar level sensor due to faults caused by incorrect operation, and ensure The accuracy of the level sensor also extends the service life of the radar level sensor.


Share to
RELATED NEWS / News More
  • Number of clicks: 369
    2021 - 07 - 27
    Radar level transmitter are currently widely used in the monitoring of solids, dust particles, liquids, slurries, river water levels, etc. The level signal detected by the radar level transmitter is ultimately connected to the back of our automation control equipment or to the secondary display meter for monitoring control. The specific power supply and communication methods are as follows:1. (4 ~ 20) mA / 24V DC / HART two-wire system2. (4 ~ 20) mA / 24V DC / HART four-wire system3. (4 ~ 20) mA / (85~ 265) V AC / HART four-wire system4. RS485/Modbus/( 6~26)V DC5. Radio frequency 433MThe customer can select the power supply and communication mode according to the actual requirements of the site. If you have any questions, please contact us directly.Xi’an Dechuang Electrical ...
  • Number of clicks: 360
    2021 - 07 - 07
    The screw connection is a widely used detachable fixed connection, which has the advantages of simple structure, reliable connection, and convenient assembly and disassembly. Thread is a key part of thread coupling and screw drive, let us take a look at the classification of thread.According to the tooth shape, it can be divided into triangle, trapezoid, rectangle, zigzag and arc thread;According to the thread rotation direction, it can be divided into left-handed and right-handed;According to the number of spiral lines, it can be divided into single line and multi-line;According to the shape of the thread matrix, it can be divided into cylinder and cone.For threaded connections of radar level transmitters, there are two most common types: G 1 1 / 2A thread; NPT thread.
  • Number of clicks: 321
    2021 - 06 - 29
    The 120GHz FMCW radar level meter successfully applied to the measurement of Chlorinated paraffin in a chemical plant.The working condition is more complicated, the surface foam thickness is about 80cm, the 120GHz radar level meter signal is relatively strong, penetrates the foam, and accurately measures the liquid level.The Main Feature of 120GHz FMCW Radar level meter:1. Not be affected by atmospheric precipitation;2. The ambient temperature is -60°C;3. Being Installed on the outside of tank;4. The antenna inside of the level transmitter is protected by fluoro plastic lens heating;5. The measuring radiation is narrow, easy to install and measurement sensibility;6. The accuracy of the level measurement can't be limited by the temperature of tank;7. Evaporation, Foa...
  • Number of clicks: 0
    2021 - 06 - 25
    Case application I The anti-corrosion radar level meter DCRD1000A5&DCRD1000C5 was successfully applied to a chemical project in Inner Mongolia Since Acid-base solutions are extremely corrosive in industrial production measurement applications, the wetted materials of equipment must be anti-corrosion materials. Our high-frequency radar level meter DCRD1000A5 and guided wave radar level gauge DCRD1000C5 are special models for corrosive conditions. Radar antennas are made of PTFE with good anti-corrosion performance, which has good sealing performance, strong corrosion resistance and stable measurement results.Any inquiry about the radar level meter, welcome to contact us at any time.
  • Number of clicks: 252
    2021 - 06 - 22
    The  Features of DCRD1000C series of Guided Wave Radar Level meter (GWR)The guided wave radar level meter is an excellent level meter with advanced technology, excellent workmanship and high precision. When the guided wave radar level meter is working, an electromagnetic pulse signal is emitted, which is transmitted to the liquid level and returned at a constant speed through a probe or a steel cable, thereby simply and accurately calculating the liquid level height.Guided wave radar level meter are currently used in a wide variety of tank containers. It is used to measure the liquid level or level of medium such as aqueous medium, acidic medium, alkaline medium, oil medium, and particles.The guided wave radar level meter (DCRD1000C series) independently developed by Xi'an Dechuan...
Email:sales@dechuang-auto.com
Adress:
Tel:86-29 88606479
Fax: 86-29 88385903
B203, Gazelle Valley, No.69 Jinye Rd, Hi-tech zone, Xi'an, Shaanxi Province, P.R.China. 710077
Copyright ©2018 - 2019 Dechuang Electrical Technology Co., Ltd SITEMAP
Rhino Cloud Provides Enterprise Cloud Services
犀牛云提供云计算服务