                                               Tips on Model Selection of Radar Liquid Level Meter  -Guided wave radar  and 26GHz radar level meter


When we select the suitable model of radar level meter, below attentions should be paid on mixing, vacuumizing, power supply and output signal during model selection of radar liquid level meter.

I. Model selection on mixing(stirring)

Guided wave radar can not be used in mixing tank because mixing strength apt to bring rope into propeller or stretch the rod-type guided wave radar, non-contact measurement high frequency or low frequency horn radar is selected.

If the lowest liquid level exceeds the mixing propeller, measurement is not be impacted. If the lowest liquid level is below the the mixing propeller, it should study the fake echo to filter the signal reflected by propeller and ensure measurement not as propeller target.

II. Model selection on vacuum 

Liquid boiling point will be much lower than the standard atmospheric pressure under the condition of vacuum. Liquids from 30℃ to 40℃ start to boil, especially reactor and vaporator. In case of vacuumizing, liquid becomes calm, and vacuumized from 1m to 3m height, with boiled bubble and small water drop. The horn radar is only selected under the condition and made some changes on site.

III. Power supply and input signal

24VDC is used for radar power supply in the market. If users require 220VAC, 220VAC, there are 4-20ma and 485 power input signal. 4-20ma is dominated for wide industrial application.  a few users use 485 for low power consumption occasion on hydrology and water conservancy, torrential flood warning, etc.



Share to
RELATED NEWS / News More
  • Number of clicks: 266
    2021 - 03 - 02
    Radar level instruments measure the distance from the transmitter/sensor (located at some high point)to the surface of a process material located further below in much the same way as ultrasonic level sensor, by measuring the time-of -flight of a traveling wave and then determine the level of the process material. They are regarded as continuous level measurement devices because they continue to measure level even as the level of the liquid in the vessel changes.The fundamental difference between a radar level instrument and an ultrasonic level instruments is the type of wave used. Radar level instruments use radio waves instead of sound waves used in ultrasonic instruments. Radio waves are electromagnetic in nature (comprised of alternating electric and magnetic fields), with very high fr...
  • Number of clicks: 2
    2021 - 02 - 25
    The working principle and five precautions for using the radar level sensorThe radar level sensor is a measuring instrument based on the time travel principle. The radar wave runs at the speed of light, and the running time can be converted into a level signal by electronic components. The probe sends out high-frequency pulses and conducts them along the cable and rod probes. When the pulses meet the surface of the material, they are reflected back by the receiver in the meter, and the distance signal is converted into a level signal, Transmit-reflect-receive is the basic working principle of radar level sensor.The antenna of the radar sensor emits electromagnetic wave signals in the form of beams. The emitted waves are reflected on the surface of the material to be measured, and the ...
  • Number of clicks: 212
    2021 - 02 - 23
    Our DCRD1000C series guided wave radar level gauge has been successfully applied to the measurement of liquid level in a horizontal tank of a biotechnology company. Since the product is installed and used, it has monitored the liquid/corrosive liquid level changes in real time, and the signal stability measurement effect is good.If there is similar enquiry, please feel free to contact us!!!
  • Number of clicks: 101
    2021 - 02 - 19
    Factory of Radar level transmitter have resumed production  With the time going by, the Chinese New Year Holiday is over and our factory has resumed production now. The continuous level measuring products include 26GHz high frequency radar level transmitter, guided wave radar level transmitter, 80Ghz FMCW Radar  level transmitter, 120Ghz FMCW Radar level transmitter and Electromagnetic flow meter. These products are widely used in electricity, water, food & beverage, petroleum, petrochemical, coal, chemical, metallurgy industries. Measurable products: petroleum, petroleum products, heavy oil, asphalt, gasoline and other light-colored petroleum products, acid, food, beer, alcohol, milk, liquefied gas, sewage, solution, phenol, ore, cement, seeds, coal ...
  • Number of clicks: 361
    2021 - 02 - 02
    The radar level transmitter should be installed to avoid contact between the sensor and the tank wall and should be kept at a certain distance from the tank wall. Because the radar level transmitter is measured by transmitting high-frequency microwave pulses along the detection component, the dielectric constant changes when these pulse waves encounter the measured medium, causing the emission. Therefore, if the installed radar level transmitter is too close to the tank wall, the dielectric constant of the tank wall may be obtained, which directly leads to the in accuracy of the measured parameters.Correct installation method of radar level transmitter:1. Installed one fourth or sixth of diameter.Note:the minimum distance from the tank wall shall be one tenth ...
Email:sales@dechuang-auto.com
Adress:
Tel:86-29 88606479
Fax: 86-29 88385903
B203, Gazelle Valley, No.69 Jinye Rd, Hi-tech zone, Xi'an, Shaanxi Province, P.R.China. 710077
Copyright ©2018 - 2019 Dechuang Electrical Technology Co., Ltd SITEMAP
Rhino Cloud Provides Enterprise Cloud Services
犀牛云提供云计算服务