Radar level instruments measure the distance from the transmitter/sensor (located at some high point)to the surface of a process material located further below in much the same way as ultrasonic level sensor, by measuring the time-of -flight of a traveling wave and then determine the level of the process material. They are regarded as continuous level measurement devices because they continue to measure level even as the level of the liquid in the vessel changes.

The fundamental difference between a radar level instrument and an ultrasonic level instruments is the type of wave used. Radar level instruments use radio waves instead of sound waves used in ultrasonic instruments. Radio waves are electromagnetic in nature (comprised of alternating electric and magnetic fields), with very high frequency in the microwave frequency range - GHz.


There are two basic types of level radar instruments: guided-wave radar and non-contact wave radar. Guided-wave radar instruments use wave guide 'probes' to guide the radio waves into the process liquid while non-contact radar instruments send radio waves out through open space to reflect off process material. Note that guide-wave radar instruments are used in applications where the dielectric of the process liquid is quiet low. All radar level instruments use an antenna to broadcast or send radio signals to the process liquid whose level is to be determined. The diagram below illustrates these two approaches:

Operating Principle of Non-Contacting Radar Level Sensor/Gauges (Unguided Wave)

Operating Principle of Non-Contact Radar Level Sensor


To measure the level of a liquid or solid in this type of radar instrument, radar signals are transmitted from the antenna of a radar instrument located at the top of the tank or vessel as shown below:

Operating Principle of Non-Contacting Radar Level Sensor/Gauges (Unguided Wave)

Non-contact level measurement using radar has two main modulation techniques: pulse radar and FMCW(Frequency Modulate Continuous Wave) radar techniques.


In the pulse radar technique, pulse radar sent out a microwave signal that bounces off the product surface and returns to the gauge. The transmitter measures the time delay between the transmitted and received echo signal and on-board microprocessor calculates the distance to the liquid surface using the formula:


Distance = [Speed of Light*Time Delay]/2


To calculate liquid level, the transmitter is programmed with the reference gauge height of the application (as show above)-usually the bottom of the tank or chamber. The liquid level is then calculated by the microprocessor in the transmitter.


In the FMCW radar technique, microwaves are transmitted towards the product surface, but the transmitted signal is of continuously varying frequency. When the signal has travelled down to the liquid surface and back to the antenna, it is mixed with the signal that is being transmitted at the same time. The difference in frequency between the received and transmitted signal is directly proportional to the distance to the liquid with high precision.


The frequency of non-contacting radar sensors can impact its performance. A lower frequency reduces sensitivity to vapor, foam and contamination of the antenna, whereas a higher frequency keeps the radar beam narrow in order to minimize influence from nozzles, walls and disturbing objects. Beam width is inversely proportional to antenna size. The beam width of a given frequency will decrease as the antenna size increase.


Non-contact radar sensor can be used in application from 1m to 70m.


Accuracy Level of Radar Instruments


The achievable accuracy of any radar level measurement system depends heavily on the type of application, the antenna design, mechanical installation, the state and quality of the electronics and echo processing softwave employed. Even though the effects of temperature and pressure variations are very small, compensation methods are still being used for these parameters. Other influences on accuracy of radar level instrument include to noise radio and interference.


Areas of Application


Radar level instruments are widely used to measure the level of liquid, slurries as well as many solids in storage tank refineries and tank terminal. These instruments operate in a wide range of temperature, pressure, vapor das mixtures and various process conditions.


Application Limitations


Solid


Radar level instruments are quite specific in their application of use. Radar level instrument should be avoided as much of possible on the solids due to the weak signal reflection that occurs.


Low Dielectric Process Fluids


Non-contact radar sensors perform poorly with low dielectric process fluids. With low dielectric process fluid, much of the radiated energy is lost to the fluid, leaving very little energy to be reflected back to the gauge. Water and most chemical solution have a high dielectric constant; fuel oil, lube oil and some solids, such as lime, have a low dielectric constant. Their application is not suitable for these kinds of low dielectric fluids.


Surface Turbulence


If the surface is turbulent, whether from agitation, product blending, or splashing, more of the signal is lost. A combination of a low dielectric fluid and turbulence can limit the return signal to a non-contact radar sensor. To solve the problem of turbulence, bypass pipes or stilling wells can be used to isolate the surface from the turbulence.


Advantages


Used on difficult 'hard-to-handle' applications

High accuracy

Non-contact

Can measure level through plastic tanks

Used to monitor contents of boxes or other multi-media material

Detect obstructions in chutes or presses


Disadvantages


Very sensitive to build-up on sensor surface

They are very expensive. Price increases with increasing accuracy.


Share to
RELATED NEWS / News More
  • Number of clicks: 100
    2020 - 11 - 26
    Instrument Knowledge|Application of radar level transmitter in natural gas chemical industry chainNatural gas chemical industry is one of the branches of the chemical industry. It is an industry that uses natural gas as a raw material to produce chemical products. Natural gas chemical industry can also be attributed to petrochemical industry. Generally include the purification and separation of natural gas and chemical processing. Through purification, separation and cracking, steam reforming, oxidation, chlorination, sulfurization, nitration, dehydrogenation and other reactions, it can be made into synthetic ammonia, methanol and its processed products (formaldehyde, dimethyl ether, acetic acid, olefin, etc.), acetylene and its deep processing Products, etc. Purification and separati...
  • Number of clicks: 291
    2020 - 11 - 24
    There are many corrosive liquid used in various chemical industries, then the corrosive liquid level measuring instrument are required commonly, For radar type level sensor, we have below 3 types of anti-corrosion:1. DCRD1000A1, PTFE corrosive proof radar level sensor2. DCRD1000A2, PFA corrosive proof radar level sensor3. DCRD1000C5, FEP corrosive proof radar level sensorXi’an Dechuang Electrical Technology Co., Ltd
  • Number of clicks: 1001
    2020 - 11 - 19
    120G frequency modulated continuous level measurements radar level meter was successfully applied to the level measurement of aluminum foil waste in high temperature kilns The measuring medium is various aluminum blocks, aluminum foil scraps, etc.The aluminum foil is very light during the feeding process, and there are many flying materials and suspended aluminum foils, and the temperature in the furnace is as high as 700-800 degrees. This environment also has a great impact on the installation of the continuous radar level meter. After technical discussions with us, the customer finally chose our DCRD1000B3 120Ghz radar level meter high temperature type, combined with specific site conditions, added a section of extension pipe and quartz glass for heat insulation, the technical ...
  • Number of clicks: 352
    2020 - 11 - 17
    Air purge+Nuzzle ,  Universal joint:The necessary adjunct when measuring the level of bulk solid in silos bins and tanksWhen radar level transmitter measure the level of solid medium, such as grains, cement powders, solid particles,  the solid material  will form a stockpile or hopper in the silo when feeding  or undloading. Then the antenna of the radar level transmitter need to perpendicularly alignment to the medium surface,  if the material is uneven,  and the heap angle is large then the universal joint flange is needed to adjust the horn angle to aim the charge level.(Due to the inclination of the solid surface it will cause the problem of  echo decay or even the signal loss.)When measuring the bulk solids, there will bring very heavy dust.  we...
  • Number of clicks: 201
    2020 - 11 - 13
    Application case | 120G frequency modulated radar level gauge DCRD1000B successfully applied to the measurement of liquid level in the pharmaceutical and chemical reactor The chemical and pharmaceutical industry has the characteristics of complex production technology, many varieties, long process flow, many types of equipment required, many raw and auxiliary materials, and most of them are flammable, explosive and toxic, and have the characteristics of stimulating corrosion. As a liquid level measuring instrument installed on a storage tank or reactor, the liquid level gauge is also faced with technical performance challenges in the face of the complex structure and harsh working conditions of the equipment in the pharmaceutical and chemical industry. DCRD1000B series, 120GHz fr...
Email:sales@dechuang-auto.com
Adress:
Tel:86-29 88606479
Fax: 86-29 88385903
B203, Gazelle Valley, No.69 Jinye Rd, Hi-tech zone, Xi'an, Shaanxi Province, P.R.China. 710077
Copyright ©2018 - 2019 Dechuang Electrical Technology Co., Ltd SITEMAP
Rhino Cloud Provides Enterprise Cloud Services
犀牛云提供云计算服务