HOTLINE 0086-29-88606479
  Tel: 86-29-88606479   E-mail: sales@dechuang-auto.com

NEWS

About us

the Installation Position Selection Of Radar Level Sensor 2/2

DATE: 2019-06-05
BROWSE TIMES: 70

the Installation Position Selection Of Radar Level Sensor  2/2

Connect to the previous article....

 

The radar level Sensor should be installed to avoid contact between the sensor and the tank wall and should be kept at a certain distance from the tank wall. Because the radar level meter is measured by transmitting high-frequency microwave pulses along the detection component, the dielectric constant changes when these pulse waves encounter the measured medium, causing the emission. Therefore, if the installed radar level sensor is too close to the tank wall, the dielectric constant of the tank wall may be obtained, which directly leads to the inaccuracy of the measured parameters.

 

Correct installation method of radar level Sensor:

 

5. The Radar level sensor can not be installed in the middle of the arch and round tank top. When the radar sensor is installed in the middle of the arched and rounded tank top, not only the indirect echo but also the multiple echoes will be received. The multiple echoes may be larger than the threshold of the true echo signal, because the top can be concentrated by multiple echoes.

As Shown: ① right ② wrong

 the Installation Position Selection Of Radar Level Sensor  2/2

6. When the tank obstacles affect the measurement, the baffle-board must be installed for proper measurement.

As Shown: ① right ② wrong

the Installation Position Selection Of Radar Level Sensor  2/2 

7. The pipe joint height requirements, it must ensure that the antenna extends into the tank for at least 10mm

  the Installation Position Selection Of Radar Level Sensor  2/2

Xi’an Dechuang Electrical Technology Co., Ltd

Website:  www.dechuang-auto.com


Share to
RELATED NEWS / News More
  • Number of clicks: 295
    2021 - 01 - 19
    The 120G frequency-modulated continuous wave radar level meter has been successfully applied to the material level monitoring of slaked lime in a chemical factory in Inner Mongolia.The storage tank environment is complex and the smoke dust is very large. They used the imported radar level meter before, but the horn antenna was easy to be dusted,then the measurement become not accurate after a short period of time.After the technical communication of our company, the 120G frequency-modulated continuous wave radar level meter installed by our company has better on-site test signals, the test data is accurate and has been recognized by customers.NOT FAMOUS BRAND, BUT STRONG STRENGTH!-----------------------120GHz FMCW Radar level Meter DCRD1000BXi’an Dechuang Electrical Technology Co...
  • Number of clicks: 107
    2020 - 12 - 03
    Industry knowledge|The application of Radar level Transmitter in the process flow of steel production in the metallurgical industry  The metallurgical industry refers to the mining, beneficiation, and sintering of metal ores, smelting and processing them into metal materials. Divided into: (1) Ferrous metallurgical industry, that is, the industrial sector that produces iron, chromium, manganese and their alloys. It mainly provides raw materials for modern industry, transportation, infrastructure and military equipment; (2) Non-ferrous metallurgical industry, which is production Non-ferrous metal refining industrial sectors, such as copper smelting, aluminum, lead-zinc, nickel-cobalt, tin smelting, precious metals, rare metals and other industrial sectors. Let's take a lo...
  • Number of clicks: 188
    2020 - 08 - 25
    Application of Radar Level Gauge in Tank Level Measurement in Petrochemical Tank Farm1. In recent years, the production of my country's petrochemical industry has been generally stable, market supply and demand have been stable, major economic indicators have grown better than expected, and the overall benefits of the industry have continued to be in a good situation. As petrochemical projects become more and more large-scale, the number and scale of storage and transportation tank farms have shown an upward trend in recent years, and the scale and capacity of single storage tanks are also increasing, from tank farm engineering design to daily routine Safety management has brought new challenges to petrochemical companies.The petrochemical tank farm has the characteristics of large-sca...
  • Number of clicks: 1009
    2020 - 04 - 11
    There are many kinds of industrial automation instruments. From information acquisition, transmission, reflection and processing, industrial automation instruments are divided into five categories: on-site testing instruments, display instruments, control instruments, actuators, and centralized testing and control devices. Each large category can be divided into some small categories. 1) Continuous level measuring instruments: buoyancy level gauge, capacitance level gauge, radar level meter (DCRD1000A series radar level gauge), laser level gauge, ray level gauge, ultrasonic level transmitter, Direct reading liquid level gauge, outside micro-shock liquid level gauge, differential pressure liquid level gauge, weight level gauge 2) Limit level measuring instruments:&#...
  • Number of clicks: 29
    2020 - 03 - 13
    There are many aggressive liquid used in various chemical industries or medical factory, then the corrosive liquid level measuring instrument are required commonly, For radar type level sensor/meter/gauge, we have below 3 types of anti-corrosion:1. DCRD1000A1, PTFE corrosive proof radar level sensor2. DCRD1000A2, PFA corrosive proof radar level sensor3. DCRD1000C5, FEP corrosive proof radar level sensorXi’an Dechuang Electrical Technology Co., Ltd
Email:sales@dechuang-auto.com
Adress:
Tel:86-29 88606479
Fax: 86-29 88385903
B203, Gazelle Valley, No.69 Jinye Rd, Hi-tech zone, Xi'an, Shaanxi Province, P.R.China. 710077
Copyright ©2018 - 2019 Dechuang Electrical Technology Co., Ltd SITEMAP
Rhino Cloud Provides Enterprise Cloud Services
犀牛云提供云计算服务