                         the Installation Position Selection Of Radar Level Meter  1/2

The radar level meter should be installed to avoid contact between the sensor and the tank wall and should be kept at a certain distance from the tank wall. Because the radar level meter is measured by transmitting high-frequency microwave pulses along the detection component, the dielectric constant changes when these pulse waves encounter the measured medium, causing the emission. Therefore, if the installed radar level gauge is too close to the tank wall, the dielectric constant of the tank wall may be obtained, which directly leads to the inaccuracy of the measured parameters.



Correct installation method of radar level meter:

1. Installed one fourth or sixth of diameter.

Note:the minimum distance from the tank wall shall be one tenth of the tank height.

  Installation Position Selection of Radar Level Meter 1/2

2. For conical tank top plane, it can be installed on the middle of the tank top to ensure the measurement of the conical bottom.

                                       Installation Position Selection of Radar Level Meter 1/2

3. When there is a pile, the antenna should be aligned perpendicular to the surface. If the material surface is not flat and the cone angle is too large, the universal flange must be used to adjust the angle of the horn so that the horn is aligned with the material surface.(Due to the inclination of the solid surface it will cause the echo decay or even the signal loss .)

                               Installation Position Selection of Radar Level Meter 1/2

4. The radar level meter should not be installed above the inlet of the conical tank. When installing outdoors, it should be protected from sun and rain.

                                          Installation Position Selection of Radar Level Meter 1/2

..... ..... ..... 

 the Installation Position Selection Of Radar Level Meter,  not finished, to be continued.....

Share to
RELATED NEWS / News More
  • Number of clicks: 290
    2021 - 01 - 19
    The 120G frequency-modulated continuous wave radar level meter has been successfully applied to the material level monitoring of slaked lime in a chemical factory in Inner Mongolia.The storage tank environment is complex and the smoke dust is very large. They used the imported radar level meter before, but the horn antenna was easy to be dusted,then the measurement become not accurate after a short period of time.After the technical communication of our company, the 120G frequency-modulated continuous wave radar level meter installed by our company has better on-site test signals, the test data is accurate and has been recognized by customers.NOT FAMOUS BRAND, BUT STRONG STRENGTH!-----------------------120GHz FMCW Radar level Meter DCRD1000BXi’an Dechuang Electrical Technology Co...
  • Number of clicks: 101
    2020 - 12 - 03
    Industry knowledge|The application of Radar level Transmitter in the process flow of steel production in the metallurgical industry  The metallurgical industry refers to the mining, beneficiation, and sintering of metal ores, smelting and processing them into metal materials. Divided into: (1) Ferrous metallurgical industry, that is, the industrial sector that produces iron, chromium, manganese and their alloys. It mainly provides raw materials for modern industry, transportation, infrastructure and military equipment; (2) Non-ferrous metallurgical industry, which is production Non-ferrous metal refining industrial sectors, such as copper smelting, aluminum, lead-zinc, nickel-cobalt, tin smelting, precious metals, rare metals and other industrial sectors. Let's take a lo...
  • Number of clicks: 186
    2020 - 08 - 25
    Application of Radar Level Gauge in Tank Level Measurement in Petrochemical Tank Farm1. In recent years, the production of my country's petrochemical industry has been generally stable, market supply and demand have been stable, major economic indicators have grown better than expected, and the overall benefits of the industry have continued to be in a good situation. As petrochemical projects become more and more large-scale, the number and scale of storage and transportation tank farms have shown an upward trend in recent years, and the scale and capacity of single storage tanks are also increasing, from tank farm engineering design to daily routine Safety management has brought new challenges to petrochemical companies.The petrochemical tank farm has the characteristics of large-sca...
  • Number of clicks: 1005
    2020 - 04 - 11
    There are many kinds of industrial automation instruments. From information acquisition, transmission, reflection and processing, industrial automation instruments are divided into five categories: on-site testing instruments, display instruments, control instruments, actuators, and centralized testing and control devices. Each large category can be divided into some small categories. 1) Continuous level measuring instruments: buoyancy level gauge, capacitance level gauge, radar level meter (DCRD1000A series radar level gauge), laser level gauge, ray level gauge, ultrasonic level transmitter, Direct reading liquid level gauge, outside micro-shock liquid level gauge, differential pressure liquid level gauge, weight level gauge 2) Limit level measuring instruments:&#...
  • Number of clicks: 25
    2020 - 03 - 13
    There are many aggressive liquid used in various chemical industries or medical factory, then the corrosive liquid level measuring instrument are required commonly, For radar type level sensor/meter/gauge, we have below 3 types of anti-corrosion:1. DCRD1000A1, PTFE corrosive proof radar level sensor2. DCRD1000A2, PFA corrosive proof radar level sensor3. DCRD1000C5, FEP corrosive proof radar level sensorXi’an Dechuang Electrical Technology Co., Ltd
Email:sales@dechuang-auto.com
Adress:
Tel:86-29 88606479
Fax: 86-29 88385903
B203, Gazelle Valley, No.69 Jinye Rd, Hi-tech zone, Xi'an, Shaanxi Province, P.R.China. 710077
Copyright ©2018 - 2019 Dechuang Electrical Technology Co., Ltd SITEMAP
Rhino Cloud Provides Enterprise Cloud Services
犀牛云提供云计算服务