The radar level transmitter should be installed to avoid contact between the sensor and the tank wall and should be kept at a certain distance from the tank wall. Because the radar level transmitter is measured by transmitting high-frequency microwave pulses along the detection component, the dielectric constant changes when these pulse waves encounter the measured medium, causing the emission. Therefore, if the installed radar level transmitter is too close to the tank wall, the dielectric constant of the tank wall may be obtained, which directly leads to the in accuracy of the measured parameters.


Correct installation method of radar level transmitter:

1. Installed one fourth or sixth of diameter.

Note:the minimum distance from the tank wall shall be one tenth of the tank height.

 Installation Position Selection of Radar Level Meter 1/2

2. For conical tank top plane, it can be installed on the middle of the tank top to ensure the measurement of the conical bottom.

 Installation Position Selection of Radar Level Meter 1/2

3. When there is a pile, the antenna should be aligned perpendicular to the surface. If the material surface is not flat and the cone angle is too large, the universal flange must be used to adjust the angle of the horn so that the horn is aligned with the material surface.(Due to the inclination of the solid surface it will cause the echo decay or even the signal loss .)

 Installation Position Selection of Radar Level Meter 1/2

4. The radar level meter should not be installed above the inlet of the conical tank. When installing outdoors, it should be protected from sun and rain.

 Installation Position Selection of Radar Level Meter 1/2



5. The Radar level sensor can not be installed in the middle of the arch and round tank top. When the radar sensor is installed in the middle of the arched and rounded tank top, not only the indirect echo but also the multiple echoes will be received. The multiple echoes may be larger than the threshold of the true echo signal, because the top can be concentrated by multiple echoes.

As Shown: ① right ② wrong

Radar Level Transmitter's installation position

6. When the tank obstacles affect the measurement, the baffle-board must be installed for proper measurement.

As Shown: ① right ② wrong

Radar Level Transmitter's installation position

7. The pipe joint height requirements, it must ensure that the antenna extends into the tank for at least 10mm


Radar Level Transmitter's installation position


Share to
RELATED NEWS / News More
  • Number of clicks: 30
    2021 - 04 - 08
    The 80Ghz radar level meter is used in the measurement of organic liquids. The reactor contains multiple layers of stirring and has a small range; after repeated tests, the 80Ghz FMCW radar level meter has always had a stable measurement effect and accurate data, which has won the satisfaction of end users .
  • Number of clicks: 1
    2021 - 04 - 06
    1. 1 Description of productsElectromagnetic flow meter is a kind of inductional instrument designed by Faradays' law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.Besides measuring flow of general conductive liquid electromagnetic flow meter can measure flow of liquid-solid fluid, high-viscosity fluid ...
  • Number of clicks: 101
    2021 - 04 - 01
    Common problems of radar level transmitter Radar level transmitter are mainly installed in various metal and non-metal containers or pipelines to perform non-contact continuous measurement of the level of liquids, slurries and particles. It is also suitable for occasions with dust, inert gas and steam. The radar level transmitter has the characteristics of safety, cleanliness, high precision, long life, stable and reliable, convenient installation and maintenance, and simple reading. Because there are no moving parts, maintenance is minimal, but some minor faults will inevitably occur during use. Here is a breakdown analysis and countermeasures for everyone.1. If an alarm occurs when the liquid level is within the applicable range, then:a. When the liquid leve...
  • Number of clicks: 193
    2021 - 03 - 30
    Radar level meter is a common product type of level meter, which has the advantages of accurate measurement, stable performance, high reliability, easy maintenance, and wide application range. It can be installed in various metal and non-metal containers or tanks to measure the level of liquid, slurry and granular materials. So, under what special conditions will it be installed?1. Selection under the condition of stirringIn a tank with stirring, guided wave radar level gauges are generally not used. The strength of stirring can easily bring the cable of the guided wave radar into the stirring device, or bend the rod of the guided wave radar. So you can only choose non-contact measurement of FM or high-frequency horn-mouth radar level meter to measure.2. Selection under vacuum conditionsUn...
  • Number of clicks: 103
    2021 - 03 - 25
    Radar level meter measures ammonia in a fertilizer plant Ammonia refers to an aqueous solution of ammonia with a strong pungent odor and weak alkaline. Store in a cool, dry, ventilated place, away from fire and heat. Avoid direct sunlight and keep the container tightly closed. It should be stored separately from acids, metal powders, etc. Open-air storage tanks must have cooling measures in summer. Ammonia is often used in agricultural fertilizers, in the chemical industry for the manufacture of various ammonium salts, aminating agents for organic synthesis, and catalysts for the production of thermosetting phenolic resins. In the textile industry, it is used in wool spinning, silk, printing and dyeing industries, for washing wool, woolen cloth, grey cloth, oil stains, dyein...