What is the measurement effect of the 120G FMCW radar level gauge? We use the measurement data to prove. The test lasts for 4 days. The radar level gauge measurement data (echo curve and historical curve) are taken every day. The gauge automatically records the historical curve. Through the analysis and judgment of the echo curve and the historical curve, Make sure the radar level gauge is working properly.

The following is a test report of Xi'an Dechuang 120G FMCW continuous wave radar level gauge DCRD1000B in a chemical plant in Guangzhou:

 

 

                                                           120G radar level gauge trial report

 

Address: Guangzhou XXXXX Chemical Co., Ltd.

Purpose: 120G radar level gauge tested under a lot of foam conditions

Content:

1. Instrument parameters and on-site conditions:

Process connection: DN65/PN10; Medium: Chlorinated paraffin

Temperature: 90 °C ; Pressure: <1MPa

Supply voltage: DC24V ; Output: 4-20mA ; Range: 3m

Site conditions:

The working conditions are complicated, and a large amount of steam and foam are generated during the reaction (the foam thickness is up to 800 mm at the highest), and the liquid level fluctuates greatly.

2. Test process data

  The test lasts for 4 days. Every day, the meter measurement data (echo curve and historical curve) are taken. The meter automatically records the historical curve. Through the analysis and judgment of the echo curve and the historical curve, the instrument is guaranteed to work normally. The following is a 4-day meter. Record data.

                                 What is the measurement effect of the 120G FMCW radar level gauge? the measurement data to prove!

Day 1st :


                                  What is the measurement effect of the 120G FMCW radar level gauge? the measurement data to prove!

Day 2nd :

                                  What is the measurement effect of the 120G FMCW radar level gauge? the measurement data to prove!

Day 3rd :

                                  What is the measurement effect of the 120G FMCW radar level gauge? the measurement data to prove!

Day 4th : 

                                What is the measurement effect of the 120G FMCW radar level gauge? the measurement data to prove!

3. Problems

At the beginning of the reactor, a large amount of chlorine gas enters the reactor. At this time, the reaction is intense, and a large amount of foam is generated, which fills the entire reactor. Due to the excessive thickness of the foam (about 800 mm), the echo signal of the meter is weak or There is no echo, which affects the normal measurement of the meter. (Note: This condition is only generated at the beginning of feeding, and will not appear during normal production)

4. Trial results analysis and summary

After four days of on-site test of the instrument, the 120G radar level gauge satisfies the customer's requirements in a large number of foam conditions, solves the problem that many instruments cannot be measured by a large number of foam conditions, and shows that the instrument is in complex conditions. Reliability and stability. At the same time, because the instrument adopts a variety of high-tech technology, the instrument has low installation requirements, quick and easy debugging, and simple maintenance, which has been affirmed by the leadership of the trial company.


Share to
RELATED NEWS / News More
  • Number of clicks: 0
    2020 - 08 - 06
    Instrument knowledge|Precautions for installation of electromagnetic flowmeter Electromagnetic flow meters can measure conductive liquids and are widely used in chemical, chemical fiber, food, paper, sugar, mining and metallurgy, urban water supply and drainage, environmental protection, water conservancy, steel, petroleum, pharmaceuticals and other industrial fields to measure various acids , Alkali, salt solution, mud, mineral pulp, paper pulp, coal water slurry, corn steep liquor, fiber pulp, grain pulp, lime milk, sewage, etc.。Electromagnetic flowmeter has a series of excellent characteristics, which can solve the problems that other flowmeters are not easy to use, such as the measurement of dirty flow and corrosive flow. AdvantageThe measurement channel is a smooth stra...
  • Number of clicks: 211
    2020 - 08 - 04
    Instrument knowledge|The launch angle of 26GHz high frequency radar level transmitterRadar level transmitter, the pulse wave emitted during measurement can pass through the vacuum without transmission medium, and is not affected by the atmosphere, steam, and volatile media. At the same time, the pulse wave has high frequency and strong penetrating ability, even if the height of the solid silo is large. , With small diameter and strong dust, the radar level meter can also provide continuous, reliable and stable measurement results.  Among them, the DCRD1000A series sensor is a 26G high frequency radar type level measuring instrument, which has the following measurement characteristics:1. High frequency, it has obvious advantages to measure solid and low dielectric constant me...
  • Number of clicks: 0
    2020 - 07 - 30
    Tank side level monitoring from radar level transmitter factory  The DCRD1000D series tank side display (pointer) indicator is a digital display instrument for process variables. No separate power supply is needed, and it is connected in series in the loop of local instrumentation and control (DCS, PLC or control terminal). It is used to receive the 4-20mA current signal and accurately display the data corresponding to the tested loop, which is convenient for checking the value of the liquid level and material level height on site. High-definition outdoor red LED display, can also display current, percentage, etc., and output with 4-20mA current signal. This series of tank level side monitoring adopts compact structure design, easy to install and debug; it can be used in two-wire...
  • Number of clicks: 215
    2020 - 07 - 28
    Instrument knowledge|Classification of on-site detection instruments for industrial automation instrumentsThere are many types of industrial automation instruments. From the acquisition, transmission, reflection and processing of information, industrial automation instruments are divided into five categories: field measuring instruments, display instruments, control instruments, actuators, and centralized detection and control devices. Each major category can be subdivided into several subcategories. Let's take a look at the classification of on-site inspection instruments.Classification of field measuring instruments:1. Material level and liquid level meter:Continuous level measuring instruments: buoyancy level gauge, capacitive level gauge, radar level gauge (DCRD1000A series radar level...
  • Number of clicks: 0
    2020 - 07 - 23
    Successful case | Guided wave radar level meter applied to the level measurement of sodium carbonate solution in the evaporator Sodium carbonate solution, the chemical name is sodium carbonate decahydrate; washing alkali; crystal alkali; lime alkali; used as an analytical reagent, such as a reference reagent, decomposition sample solvent, precipitant, buffer, and sample volatilization aid in emission spectrum analysis. Preparation of sodium salt, soda glass and film printing and washing, carbonate precipitation agent, etc.  Guided wave radar level meter, measuring liquid level and material level, contact measurement, strong anti-interference ability, can overcome the influence of steam and foam on the measurement, the highest measurement temperature can reach 250 ℃....
Email:sales@dechuang-auto.com
Adress:
Tel:86-29 88606479
Fax: 86-29 88385903
B203, Gazelle Valley, No.69 Jinye Rd, Hi-tech zone, Xi'an, Shaanxi Province, P.R.China. 710077
Copyright ©2018 - 2019 Dechuang Electrical Technology Co., Ltd SITEMAP
Rhino Cloud Provides Enterprise Cloud Services
犀牛云提供云计算服务